4
HLV Series
1.0 IntroductionHLV Series Specifications
Burner
Model
Gas
Types
BTU/H
(High Fire)
BTU/H
(Low Fire)
Approximate System
Hanging Weights
Typical
Mounting
Height^
Combustion
Chamber
(Black Coated)
Radiant
Emitter
Tube (s)**
Condensing
Pipe
Per
Burner
Head
Per 10 Ft.
Radiant Pipe
& Reflector
Section
Per 10 Ft.
Tailpipe &
Reflector
Section
HLV- 40*
N or P
40,000 40,000
35 lbs. 35 lbs. 45 lbs.
9’ to 14’
Al-Ti
Coated Alum or
Uncoated HRT
304 Stainless
Steel
HLV- 50*
N or P
50,000 50,000
35 lbs. 35 lbs. 45 lbs.
9’ to 14’
Al-Ti
Coated Alum or
Uncoated HRT
304 Stainless
Steel
HLV- 60
N or P
60,000 50,000
35 lbs. 35 lbs. 45 lbs.
10’ to 15’
Al-Ti
Coated Alum or
Uncoated HRT
304 Stainless
Steel
HLV-75
N or P
75,000 60,000
35 lbs. 35 lbs. 45 lbs.
11’ to 18’
Al-Ti
Coated Alum or
Uncoated HRT
304 Stainless
Steel
HLV- 80
N or P
80,000 64,000
35 lbs. 35 lbs. 45 lbs.
11’ to 18’
Al-Ti
Coated Alum or
Uncoated HRT
304 Stainless
Steel
HLV-90
N or P
90,000 72,000
35 lbs. 35 lbs. 45 lbs.
12’ to 20’
Al-Ti
Coated Alum or
Uncoated HRT
304 Stainless
Steel
HLV-100
N or P
100,000 80,000
35 lbs. 35 lbs. 45 lbs.
12’ to 20’
Al-Ti
Coated Alum or
Uncoated HRT
304 Stainless
Steel
HLV-110
N or P
110,000 88,000
35 lbs. 35 lbs. 45 lbs.
13’ to 23’
Al-Ti
Coated Alum or
Uncoated HRT
304 Stainless
Steel
HLV-120
N or LP
120,000 96,000
35 lbs. 35 lbs. 45 lbs.
13’ to 25’
Al-Ti
Coated Alum or
Uncoated HRT
304 Stainless
Steel
HLV-125
N or P
125,000 100,000
35 lbs. 35 lbs. 45 lbs.
14’ to 27’
Al-Ti
Coated Alum or
Uncoated HRT
304 Stainless
Steel
HLV-140
N or P
140,000 112,000
35 lbs. 35 lbs. 45 lbs.
15’ to 30’
Al-Ti
Coated Alum or
Uncoated HRT
304 Stainless
Steel
HLV-150
N or P
150,000 120,000
35 lbs. 35 lbs. 45 lbs.
15’ to 30’
Al-Ti
Coated Alum or
Uncoated HRT**
304 Stainless
Steel
HLV-170
N or P
170,000 136,000
35 lbs. 35 lbs. 45 lbs.
16’ to 40’
Al-Ti
Coated Alum or
Uncoated HRT**
304 Stainless
Steel
HLV-175
N or P
175,000 140,000
35 lbs. 35 lbs. 45 lbs.
17’ to 42’
Al-Ti
Coated Alum or
Uncoated HRT**
304 Stainless
Steel
HLV-180
N or P
180,000 144,000
35 lbs. 35 lbs. 45 lbs.
18’ to 47’
Al-Ti
Coated Alum or
Uncoated HRT**
304 Stainless
Steel
HLV-200
N or P
200,000 160,000
35 lbs. 35 lbs. 45 lbs.
19’ to 50’
Al-Ti
Coated Alum or
Uncoated HRT**
304 Stainless
Steel
Specifications
Chart 1.1 • HLV Series Specifications
* The HLV-40 and HLV-50 do not have a reduction for low fire.
** All systems are designed to utilize either black coated aluminized steel (Alum) or uncoated hot-rolled steel (HRT)
radiant emitter tubes. On systems designed with the hot-rolled steel option, a coated aluminized steel radiant tube
(TP-26A) must be installed immediately downstream of the titanium stabilized aluminized steel (Al-Ti) combustion
chamber (TP-26B) on burner models HLV-150, 170, 175, 180 and 200 only.
^ Recommended mounting heights are provided as a guideline. Actual conditions may dictate variations from this data.
NOTE: Burner models HLV-170, 175, 180 and 200 receive TP-220 stainless steel tube clamp.